Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41.814
Filtrar
1.
Circ Cardiovasc Imaging ; 17(4): e016435, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38626096

RESUMO

Heart valve replacement has steadily increased over the past decades due to improved surgical mortality, an aging population, and the increasing use of transcatheter valve technology. With these developments, prosthetic valve complications, including prosthetic valve endocarditis, are increasingly encountered. In this review, we aim to characterize the manifestations of prosthetic valve endocarditis using representative case studies from our institution to highlight the advances and contributions of modern multimodality imaging techniques.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Idoso , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite/diagnóstico por imagem , Endocardite/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Imagem Multimodal , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/terapia
2.
Int J Mol Sci ; 25(7)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38612836

RESUMO

One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient's immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve's ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Animais , Suínos , Humanos , Criança , Xenoenxertos , Transplante Heterólogo , Engenharia Tecidual
4.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38569760

RESUMO

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Humanos , Adulto , Valva Pulmonar/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Sistema de Registros , Desenho de Prótese , Estudos Retrospectivos
5.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561823

RESUMO

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Anuloplastia da Valva Mitral/efeitos adversos , Ecocardiografia , Resultado do Tratamento
6.
J Cardiothorac Surg ; 19(1): 191, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589959

RESUMO

BACKGROUND: Fungal endocarditis is a rare but serious condition associated with high mortality rates. Various predisposing factors contribute to its occurrence, such as underlying cardiac abnormalities, cardiac surgeries, prosthetic cardiac devices, and central venous catheters. Diagnosing fungal endocarditis, particularly Aspergillus, poses challenges, often complicated by negative blood cultures. CASE PRESENTATION: This report details a case of extensive ascending aorta involvement in Aspergillus endocarditis (AE) in a 24-year-old man with a history of bioprosthesis aortic valve replacement (AVR). Three months post-AVR, he presented with pericardial effusion and aortic rupture, leading to a redo biological valved conduit aortic root replacement (Bentall surgery). Despite the intervention, the tubular graft exhibited extensive Aspergillus involvement, resulting in graft disruption and significant peri-aortic infection. A second redo procedure involving aortic homograft root replacement was performed. Unfortunately, the patient succumbed two days after the surgery. CONCLUSION: A combined approach of medical and surgical therapies is recommended to manage fungal endocarditis. Despite efforts, the mortality rate associated with Aspergillus endocarditis remains unacceptably high, with no significant difference observed between combination therapy and antifungal treatment alone. Further research is essential to explore novel therapeutic strategies and improve outcomes for patients with this challenging condition.


Assuntos
Bioprótese , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Micoses , Masculino , Humanos , Adulto Jovem , Adulto , Valva Aórtica/cirurgia , Aorta Torácica/cirurgia , Aorta/cirurgia , Endocardite/diagnóstico , Endocardite/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Bioprótese/efeitos adversos
7.
J Cardiothorac Surg ; 19(1): 192, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594705

RESUMO

BACKGROUND: Perceval-S has become a reliable and commonly used option in surgical aortic valve replacement (AVR) since its first implantation in humans 15 years ago. Despite the fact that this aortic valve has been proven efficient enough in the short and mid-term period, there is still lack of evidence for the long-term outcomes. MATERIALS AND METHODS: This is an observational retrospective study in a high-volume cardiovascular center. Pertinent data were collected for all the patients in whom Perceval-S was implanted from 2013 to 2020. RESULTS: The total number of patients was 205 with a mean age 76.4 years. Mean survival time was 5.5 years (SE = 0.26). The overall survival probability of patients undergoing aortic valve replacement with Perceval-S at 6 months was 91.0% (Standard Error SE = 2.0%), at one year 88.4% (SE = 2.3%) and at 5-years 64.8% (SE = 4.4%). A detrimental cardiac event leading to death was the probable cause of death in 35 patients (55.6%). The initiation of Transcatheter Aortic Valve Replacement (TAVR) program in our center in 2017 was associated with a decline in the number of very high-risk patients treated with sutureless bioprosthesis. This fact is demonstrated by the significant shift towards lower surgical risk cases, as median Euroscore II was reduced from 5,550 in 2016 to 3,390 in 2020. Mini sternotomy was implemented in 79,5% of cases favoring less invasive approach. Low incidence of reinterventions, patient prosthesis mismatch and structural valve degeneration was detected. CONCLUSIONS: The survival rate after aortic valve replacement with implantation of Perceval-S is satisfactory in the long-term follow-up. Cases of bioprosthesis dysfunction were limited. Mini sternotomy was used in the majority of cases. TAVR initiation program impacted on the proportion of patients treated with Perceval-S with reduction of high-risk patients submitted to surgery.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Valva Aórtica/cirurgia , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599690

RESUMO

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Cateterismo Cardíaco/métodos
10.
J Am Coll Cardiol ; 83(15): 1418-1430, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599718

RESUMO

During the past 6 decades, there have been numerous changes in prosthetic valve endocarditis (PVE), currently affecting an older population and increasing in incidence in patients with transcatheter-implanted valves. Significant microbiologic (molecular biology) and imaging diagnostic (fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography) advances have been incorporated into the 2023 Duke-International Society for Cardiovascular Infectious Diseases infective endocarditis diagnostic criteria, thus increasing the diagnostic sensitivity for PVE without sacrificing specificity in validation studies. PVE is a life-threatening disease requiring management by multidisciplinary endocarditis teams in cardiac centers to improve outcomes. Novel surgical options are now available, and an increasing set of patients may avoid surgical intervention despite indication. Selected patients may complete parenteral or oral antimicrobial treatment at home. Finally, patients with prosthetic valves implanted surgically or by the transcatheter approach are candidates for antibiotic prophylaxis before invasive dental procedures.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/terapia , Endocardite Bacteriana/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Infecções Relacionadas à Prótese/microbiologia , Endocardite/diagnóstico , Endocardite/etiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
11.
J Am Coll Cardiol ; 83(15): 1431-1443, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38599719

RESUMO

This focused review highlights the latest issues in native valve infective endocarditis. Native valve disease moderately increases the risk of developing infective endocarditis. In 2023, new diagnostic criteria were published by the Duke-International Society of Cardiovascular Infectious Diseases group. New pathogens were designated as typical, and findings on computed tomography imaging were included as diagnostic criteria. It is now recognized that a multidisciplinary approach to care is vital, and the role of an "endocarditis team" is highlighted. Recent studies have suggested that a transition from intravenous to oral antibiotics in selected patients may be reasonable, and the role of long-acting antibiotics is discussed. It is also now clear that an aggressive surgical approach can be life-saving in some patients. Finally, results of several recent studies have suggested there is an association between dental and other invasive procedures and an increased risk of developing infective endocarditis. Moreover, data indicate that antibiotic prophylaxis may be effective in some scenarios.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Humanos , Endocardite/diagnóstico , Endocardite/etiologia , Endocardite Bacteriana/diagnóstico , Tomografia Computadorizada por Raios X , Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Próteses Valvulares Cardíacas/efeitos adversos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
12.
JAMA Netw Open ; 7(4): e247525, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639933

RESUMO

Importance: Aggregated data and long-term follow-up in national health data registers offer the opportunity to compare the performance of mechanical aortic prostheses within the same population. Objective: To investigate the clinical performance of mechanical aortic valve prostheses. Design, Setting, and Participants: This nationwide cohort study included all 5224 patients who underwent primary mechanical aortic valve replacement in Sweden between January 1, 2003, and December 31, 2018. Statistical analysis was performed between May and September 2023. Exposures: Surgical aortic valve replacement with the On-X, Carbomedics, Bicarbon, Standard, Regent, Open Pivot, Masters, or Advantage valve models. Main Outcomes and Measures: The primary outcome was all-cause mortality, and secondary outcomes were reintervention, heart failure, major bleeding, stroke, and embolic events. Regression standardization was used to account for baseline differences. Results: Overall, 5224 patients (mean [SD] age, 56.8 [11.7] years; 3908 men [74.8%]) were included. Total follow-up time was 43 982 person-years (mean [SD], 8.4 [4.6] years; maximum, 17.2 years). After regression standardization, there was a significant difference in 10-year mortality between the Carbomedics model group (17%; 95% CI, 15%-18%), Regent model group (17%; 95% CI, 13%-20%), and Standard model group (17%; 95% CI, 14%-19%) compared with the Bicarbon model group (27%; 95% CI, 21%-34%). Conclusions and Relevance: In this cohort study of mechanical valve surgical aortic replacement outcomes in Sweden, the rate of all-cause mortality was higher in the Bicarbon group than in the Carbomedics, Regent, and Standard model groups. These findings warrant further research on the long-term clinical performance of the Bicarbon valve.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Masculino , Humanos , Pessoa de Meia-Idade , Valva Aórtica/cirurgia , Estudos de Coortes , Desenho de Prótese
14.
J Cardiothorac Surg ; 19(1): 219, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627820

RESUMO

OBJECTIVES: Thrombocytopenia following Perceval aortic valve replacement has been described previously with variable outcome. Studies have lacked a robust analysis of platelet fluctuation and factors affecting it. We aimed to statistically describe the trend in thrombocyte variability as compared with conventional aortic valve replacement, and to assess predictors as well as impact on associated outcomes. METHODS: One hundred consecutive patients with first-time Perceval were retrospectively compared to 219 patients after Perimount Magna Ease valve replacement. The primary outcome was the serial thrombocyte count on day 0-6. Generalized estimating equations were used to analyse the data using fixed-effect models: for the effect of the post-operative day on platelet count, and random-effect models estimating both time-variant (platelets) and time in-variant variables (valve type, age, LV function, pre-op platelet level). RESULTS: Perceval patients were older (72 ± 1 vs 68 ± 1 years, p < 0.01) with higher NYHA status (3(2-3) vs 2(1-2), p < 0.001). Mean platelet count in the sutureless group was lowest on day 2 (91.9 ± 31.6 vs 121.7 ± 53.8 × 103 µl-1), and lower on day 4 (97.9 ± 44) and 6 (110.6 ± 61) compared to the conventional group (157.2 ± 60 and 181.7 ± 79) but did not result in a higher number of transfusions, bleeding or longer hospital stay (p > 0.05). Reduced platelet count was a strong predictor of red cell transfusion in the conventional (p = 0.016), but not in the sutureless group (p = 0.457). Age (Coef -1.025, 95%CI-1.649--0.401, p < 0.001) and CPB-time (Coef 0.186, 95%CI-0.371--0.001, p = 0.048) were predictors for lower platelet levels. CONCLUSION: Considering the older patient profile treated with Perceval, postoperative thrombocytopenia does not impact on outcome in terms of transfusions, complications or hospital stay.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Trombocitopenia , Humanos , Valva Aórtica/cirurgia , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Bioprótese/efeitos adversos , Desenho de Prótese , Próteses Valvulares Cardíacas/efeitos adversos , Trombocitopenia/etiologia , Fatores de Risco , Progressão da Doença
15.
J Cardiothorac Surg ; 19(1): 174, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576006

RESUMO

BACKGROUND: There is ambiguity in the literature regarding the continuous suture technique (CST) for aortic valve replacement (AVR). At our center, there has been a gradual shift towards CST over the interrupted pledgeted technique (IPT). This study aims at comparing outcomes for both techniques. METHODS: We performed a retrospective analysis of a single-center study of patients undergoing AVR between January 2011 and July 2020. Patients were divided into two groups: Continuous suture technique and interrupted pledget-reinforced sutures. The pre-operative and In-hospital clinical characteristics and echocardiographic hemodynamics (i.e. transvalvular gradients and paravalvular leakage) were compared between CST and IPT. RESULTS: We compared 791 patients with CST to 568 patients with IPT (median age: 73 and 74 years, respectively, p = 0.02). In CST there were 35% concomitant procedure vs. 31% in IPT (p = 0.16). Early mortality was 3.2% in CST versus 4.8% in IPT (p = 0.15), and a second cross-clamp due to a paravalvular-leak in 0.5% vs. 1.2%, respectively (p = 0.22). The CST was not associated with new-onset conduction-blocks mandating pacemaker implants(OR 1.07, 95% CI 0.54-2.14; P = 0.85). The postoperative gradients on echocardiography were lower in CST compared to IPT, especially in smaller annuli (peak gradients: 15.7mmHg vs. 20.5mmHg, in valve size < 23 mm, p < 0.001). CONCLUSIONS: The continuous suture technique was associated with lower postoperative gradients and shorter cross-clamp time compared to interrupted pledgeted technique. Differences in paravalvular leaks were non-significant, although slightly less in the continuous suture technique. There were no further differences in valve-related complications. Hence, continues suture technique is safe, with better hemodynamics compared to the interrupted pledgeted technique. This may be of clinical importance, especially in smaller size annular size.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Idoso , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Técnicas de Sutura , Resultado do Tratamento , Desenho de Prótese
16.
J Cardiothorac Surg ; 19(1): 176, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576022

RESUMO

BACKGROUND: Mechanical heart valve replacement is a standard treatment for severe valvular disorders. The use of mono-leaflet valves has decreased recently. Recognizing the echocardiographic features of mono-leaflet and bileaflet valves is crucial for accurate complication diagnosis and proper management. CASE PRESENTATION: A 65-year-old female with mono-leaflet mitral and bileaflet tricuspid valves underwent an echocardiographic assessment. This simple educational case provides a unique opportunity to compare the echocardiographic features of these valves within a single patient. CONCLUSION: There is a crucial need for clinicians, particularly those in training, to differentiate between mono-leaflet and bileaflet mechanical heart valves adeptly. With mono-leaflet valves decreasing in prevalence, proficiency in recognizing the echocardiographic nuances of each type is imperative. Failure to do so may result in misdiagnoses and inappropriate management. This underscores the significance of continuous education and vigilance in echocardiographic assessments to ensure optimal patient care.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral , Feminino , Humanos , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Desenho de Prótese
17.
Echocardiography ; 41(4): e15804, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38578295

RESUMO

A 60-year-old man presented with breathlessness. Nearly four decades previously, he had required three operations for Staphylococcus aureus infective endocarditis of the tricuspid valve and had received a bioprosthetic valve. He had critical tricuspid bioprosthesis stenosis which was treated successfully by valve-in-valve transcatheter tricuspid valve replacement using a balloon-expandable transcatheter heart valve. One year after intervention, the patient is well with no tricuspid valve stenosis or regurgitation.


Assuntos
Bioprótese , Endocardite Bacteriana , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Estenose da Valva Tricúspide , Masculino , Humanos , Pessoa de Meia-Idade , Adulto , Bioprótese/efeitos adversos , Constrição Patológica , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Estenose da Valva Tricúspide/diagnóstico por imagem , Estenose da Valva Tricúspide/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/cirurgia , Resultado do Tratamento , Desenho de Prótese , Falha de Prótese
18.
Braz J Cardiovasc Surg ; 39(2): e20220436, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426701

RESUMO

INTRODUCTION: The aim of this study was to assess the impact of aortic angulation (AA) on periprocedural and in-hospital complications as well as mortality of patients undergoing Evolut™ R valve implantation. METHODS: A retrospective study was conducted on 264 patients who underwent transfemoral-approach transcatheter aortic valve replacement with self-expandable valve at our hospital between August 2015 and August 2022. These patients underwent multislice computer tomography scans to evaluate AA. Transcatheter aortic valve replacement endpoints, device success, and clinical events were assessed according to the definitions provided by the Valve Academic Research Consortium-3. Cumulative events included paravalvular leak, permanent pacemaker implantation, new-onset stroke, and in-hospital mortality. Patients were divided into two groups, AA ≤ 48° and AA > 48°, based on the mean AA measurement (48.3±8.8) on multislice computer tomography. RESULTS: Multivariable logistic regression analysis was performed to identify predictors of cumulative events, utilizing variables with a P-value < 0.2 obtained from univariable logistic regression analysis, including AA, age, hypertension, chronic renal failure, and heart failure. AA (odds ratio [OR]: 1.73, 95% confidence interval [CI]: 0.89-3.38, P=0.104), age (OR: 1.04, 95% CI: 0.99-1.10, P=0.099), hypertension (OR: 1.66, 95% CI: 0.82-3.33, P=0.155), chronic renal failure (OR: 1.82, 95% CI: 0.92-3.61, P=0.084), and heart failure (OR: 0.57, 95% CI: 0.27-1.21, P=0.145) were not found to be significantly associated with cumulative events in the multivariable logistic regression analysis. CONCLUSION: This study demonstrated that increased AA does not have a significant impact on intraprocedural and periprocedural complications of patients with new generation self-expandable valves implanted.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Próteses Valvulares Cardíacas , Hipertensão , Falência Renal Crônica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Falência Renal Crônica/etiologia , Falência Renal Crônica/cirurgia , Insuficiência Cardíaca/cirurgia , Hipertensão/etiologia
19.
Braz J Cardiovasc Surg ; 39(2): e20230221, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426718

RESUMO

INTRODUCTION: Aortic valve replacement (AVR) is often recommended for patients with severe aortic stenosis or chronic aortic regurgitation. These conditions result in remodeling of the left ventricle, including increased interstitial fibrosis that may persist even after AVR. These structural changes impact left ventricular (LV) mechanics, causing compromised LV diameter to occur earlier than reduced LV ejection fraction (LVEF). The aim of this study was to examine the effect of left ventricular end-diastolic diameter (LVEDD) and its role in aortic expansion one year after AVR. METHODS: Sixty-three patients who underwent AVR were evaluated. All patients underwent standard transthoracic echocardiography, which included measurements of the ascending aorta, aortic root, LVEF, and LVEDD before the surgery and one year postoperatively. Correlations between these variables were calculated. RESULTS: All patients underwent AVR with either a mechanical or biological prosthetic aortic valve. Following AVR, there was a significant decrease in the dimensions of the ascending aorta and aortic root (both P=0.001). However, no significant changes were observed in LVEDD and LVEF. Correlations were found between the preoperative ascending aortic size and the preoperative and one-year postoperative LVEDD (r=0.419, P=0.001 and r=0.320, P=0.314, respectively). Additionally, there was a correlation between the postoperative ascending aortic size and the preoperative and one-year postoperative LVEDD (r=0.320, P=0.003 and r=0.136, P=0.335, respectively). CONCLUSION: The study findings demonstrate a significant correlation between the size of the aortic root and ascending aorta, before and after AVR. Additionally, a notable correlation was observed between postoperative LVEDD and the size of the aortic root.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ventrículos do Coração/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia
20.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-38465492

RESUMO

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Assuntos
Insuficiência da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Feminino , Humanos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tórax , Próteses Valvulares Cardíacas/efeitos adversos , Dor no Peito/etiologia , Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...